view docs/manual/x36.html @ 345:e95f07cbce4e

Update manual to reflect lwlink support for S-record output
author William Astle <lost@l-w.ca>
date Thu, 09 Apr 2015 12:35:24 -0600
parents b30091890d62
children
line wrap: on
line source

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN""http://www.w3.org/TR/html4/loose.dtd">
<HTML
><HEAD
><TITLE
>Motorola S-Record</TITLE
><META
NAME="GENERATOR"
CONTENT="Modular DocBook HTML Stylesheet Version 1.79"><LINK
REL="HOME"
TITLE="LW Tool Chain"
HREF="index.html"><LINK
REL="UP"
TITLE="Output Formats"
HREF="c21.html"><LINK
REL="PREVIOUS"
TITLE="ASCII Hexadecimal"
HREF="x32.html"><LINK
REL="NEXT"
TITLE="Intel Hex"
HREF="x41.html"></HEAD
><BODY
CLASS="SECTION"
BGCOLOR="#FFFFFF"
TEXT="#000000"
LINK="#0000FF"
VLINK="#840084"
ALINK="#0000FF"
><DIV
CLASS="NAVHEADER"
><TABLE
SUMMARY="Header navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TH
COLSPAN="3"
ALIGN="center"
>LW Tool Chain</TH
></TR
><TR
><TD
WIDTH="10%"
ALIGN="left"
VALIGN="bottom"
><A
HREF="x32.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="80%"
ALIGN="center"
VALIGN="bottom"
>Chapter 2. Output Formats</TD
><TD
WIDTH="10%"
ALIGN="right"
VALIGN="bottom"
><A
HREF="x41.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
></TABLE
><HR
ALIGN="LEFT"
WIDTH="100%"></DIV
><DIV
CLASS="SECTION"
><H1
CLASS="SECTION"
><A
NAME="AEN36"
>2.4. Motorola S-Record</A
></H1
><P
>This ASCII format consists of a series of CR+LF terminated "records" of ASCII
text. Each record has the following structure: a start-of-record character
"S", an ASCII record type digit (0-9), a two-digit ASCII hex byte count, a 
four-digit ASCII hex address, an optional sequence of two-digit ASCII hex data
values, and a two-digit ASCII hex checksum. The LW tool chain issues only S0, 
S1, S5 and S9 record types. S1 records are limited to maximum of 16 data bytes
in length, and  paragraph alignment of addresses is favored. The address
sequence of the S-Records directly follows that of the source file; multiple
ORG directives in the source code may result in out-of-sequence addresses in
the S-Record output. </P
><P
>Motorola S-Record format is a standard ASCII format accepted by most memory
device programming equipment. It is particularly useful when the assembled 
code output is destined to reside within an EPROM or Flash memory device,
for example.</P
><P
>LWASM can output this format since version 4.10. LWLINK can output this format
since version 4.11.</P
></DIV
><DIV
CLASS="NAVFOOTER"
><HR
ALIGN="LEFT"
WIDTH="100%"><TABLE
SUMMARY="Footer navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
><A
HREF="x32.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="index.html"
ACCESSKEY="H"
>Home</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
><A
HREF="x41.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
>ASCII Hexadecimal</TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="c21.html"
ACCESSKEY="U"
>Up</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
>Intel Hex</TD
></TR
></TABLE
></DIV
></BODY
></HTML
>