view docs/manual/x800.html @ 473:8181ddd707f1

Add "nooutput" pragma Add the "nooutput" pragma which causes assembly to proceed as normal for code with the exception that no output is generated for any instructions under this pragma. The current address is increased as usual and the symbol table is still constructed. However, no actual output is generated for lines operating under this pragma.
author William Astle <lost@l-w.ca>
date Thu, 01 Nov 2018 23:07:03 -0600
parents cad5937314cb
children
line wrap: on
line source

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN""http://www.w3.org/TR/html4/loose.dtd">
<HTML
><HEAD
><TITLE
>Convenience Instructions</TITLE
><META
NAME="GENERATOR"
CONTENT="Modular DocBook HTML Stylesheet Version 1.79"><LINK
REL="HOME"
TITLE="LW Tool Chain"
HREF="index.html"><LINK
REL="UP"
TITLE="LWASM"
HREF="c62.html"><LINK
REL="PREVIOUS"
TITLE="Assembler Modes and Pragmas"
HREF="x659.html"><LINK
REL="NEXT"
TITLE="Cycle Counts"
HREF="x805.html"></HEAD
><BODY
CLASS="SECTION"
BGCOLOR="#FFFFFF"
TEXT="#000000"
LINK="#0000FF"
VLINK="#840084"
ALINK="#0000FF"
><DIV
CLASS="NAVHEADER"
><TABLE
SUMMARY="Header navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TH
COLSPAN="3"
ALIGN="center"
>LW Tool Chain</TH
></TR
><TR
><TD
WIDTH="10%"
ALIGN="left"
VALIGN="bottom"
><A
HREF="x659.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="80%"
ALIGN="center"
VALIGN="bottom"
>Chapter 3. LWASM</TD
><TD
WIDTH="10%"
ALIGN="right"
VALIGN="bottom"
><A
HREF="x805.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
></TABLE
><HR
ALIGN="LEFT"
WIDTH="100%"></DIV
><DIV
CLASS="SECTION"
><H1
CLASS="SECTION"
><A
NAME="CONVINST"
>3.11. Convenience Instructions</A
></H1
><P
>&#13;Similar to the 6800 compatibility instructions (pragma 6800compat) these
pragma 6809conv and pragma 6309conv enable convenience extensions to the
6809 and 6309 instruction set.  Originally intended for compatibility with
the MACRO-80c assembler, these have proven useful in large codebases that
target both the 6809 and the 6309.</P
><P
>&#13;The 6809 extensions are straightforward with the exception of "TSTD" which
assembles as "STD -2,S".  A benefit of using these is they will "just work"
and take on their 6309 equivalent when you enable 6309 assembly mode. 
Supported instructions: ASRD, CLRD,   COMD,   LSLD,   LSRD,   NEGD,   TSTD.</P
><P
>&#13;6309 extensions are based on common patterns described by Chris Burke and
Darren Atkinson in their 6309 documentation and include the following
instructions: ASRQ,   CLRQ,   COMQ,   LSLE,   LSLF,   LSLQ,   LSRQ,   NEGE,
   NEGF,   NEGW,   NEGQ,   TSTQ.</P
></DIV
><DIV
CLASS="NAVFOOTER"
><HR
ALIGN="LEFT"
WIDTH="100%"><TABLE
SUMMARY="Footer navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
><A
HREF="x659.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="index.html"
ACCESSKEY="H"
>Home</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
><A
HREF="x805.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
>Assembler Modes and Pragmas</TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="c62.html"
ACCESSKEY="U"
>Up</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
>Cycle Counts</TD
></TR
></TABLE
></DIV
></BODY
></HTML
>